Homes will either have multiple small grilles throughout or a single large grille installed in either ceilings or walls.
Cold air return in floor or wall.
The problem comes when you use both heating and air conditioning.
Ceiling or wall grate for return air intake or heat vents.
However in one location there is a heat duct within 5 feet of the return air vent both at the floor.
Heat rises to the top the cold air return is then pulling the coldest air in the room to the furnace this negative air pressure brings the hot air down and gives the room a more consistent temp.
In a heating climate the return duct goes near the floor to draw off the cold air and heat it up.
In most homes the builders will use the wall cavity as a cold air return.
The return air vent openings need to be on the opposite side of the room so the conditioned air is pulled across the room.
I feel he put in the minimum return air vents.
It differs from a register because it does not have a damper to control airflow.
The function of a grille is to pull air from a room to return it to the heating or cooling system.
He claims that this method pulls the heat down from the ceiling and warms the room.
By putting the cold air return on the floor it will vacuum up the cold air on the floor and draw down the warm air from the ceiling.
2 1 4 x 10 overall size 3 1 2 x 12 cast iron grill without damper zm ir 210 3 0 out of 5 stars 1.
He installed the return air vents in the wall cavity but they are only 1 inch above the floor.
In an air conditioning climate the return duct goes near the ceiling to draw off the hot air and cool it down.
This pulls the air across your body.
A cold air return is for cold air other wise it would be called just a return.
And at the floor.
If you could see the air come out of the floor registers you d see it be pulled across and up through the room.
If you have this type of air return system in your home then you can have a vent at the ceiling and at the floor.
The return vent pulls cold air from the bottom of the room and returns it to the furnace to be reheated and returned as warm air.
Step 2 place your cold air return vents on the inside walls of buildings at the lowest point.
If you are in the far north or in the southern us the answer is simple.
That means the space between two wall studs.
If the supply ducts are in the floor then the return air should be located up high.
Because your body is in this path way you get the benefit of either hot air or cold air being drawn across your skin providing you comfort.
Unlike supply vents return vents do not need to be cased in metal.
Supply air from furnaces and air conditioners should be on outside walls.